When auto switch is set on the mounting side as shown below, allow at
least 2 mm run off space on mounting plate since the auto switch is
protruded from the gripper edge.
To set the auto switch, insert the auto switch into the auto switch
installation groove of the gripper from the direction indicated in the
following drawing. After setting the position, tighten the attached auto
switch mounting screw with a flat head watchmaker’s screwdriver.
1) To set the auto switch, insert the auto switch into the installation
groove of the cylinder as shown below and set it roughly.
(2) Insert the auto switch into the auto switch bracket installation groove.
(3) After confirming the detecting position, tighten the set screws (M2.5)
attached to the auto switch and set it.
(4) Be sure to change the detecting position in the state of (2).
? Refer to the dimension table.
? When auto switches are used, side mounting with through-holes is not possible.
Note 1) Normally open type plug position.
Note 2) Normally closed type plug position.
The plug is mounted on only one side for the single acting type.
021-39526589
網址:www.hnjgt.net
地 址:上海市嘉定區嘉涌路99弄
6號樓713室